Fujitsu Siemens Computers PRIMERGY TX150 S6 (Intel Xeon X3360) SPECpower_ssj2008 = 1,018 overall ssj_ops/watt
Test Sponsor: Fujitsu Siemens Computers SPEC License #: 22 Test Method: Single Node
Tested By: Fujitsu Siemens Computers Test Location: Paderborn, Germany Test Date: Mar 26, 2008
Hardware Availability: Mar-2008 Software Availability: Feb-2008 Publication: Apr 2, 2008
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.5% 184,145 116 1,586
90% 90.1% 166,892 113 1,475
80% 79.7% 147,598 109 1,351
70% 70.5% 130,538 105 1,243
60% 59.7% 110,607 99.4 1,113
50% 49.4% 91,420 93.0 983
40% 40.6% 75,086 86.5 868
30% 30.1% 55,795 79.0 706
20% 20.0% 37,116 72.3 514
10% 10.0% 18,424 66.0 279
Active Idle 0 59.3 0
∑ssj_ops / ∑power = 1,018
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: PRIMERGY TX150 S6 (Intel Xeon X3360)
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Fujitsu Siemens Computers
Model: PRIMERGY TX150 S6 (Intel Xeon X3360)
Form Factor: --
CPU Name: Intel Xeon X3360
CPU Characteristics: 2.83GHz, 2x6MB L2 Cache, 1333MHz system bus
CPU Frequency (MHz): 2833
CPU(s) Enabled: 4 cores, 1 chip, 4 cores/chip
Hardware Threads: 4 (1 / core)
CPU(s) Orderable: 1
Primary Cache: 32KB I + 32KB D on chip per core
Secondary Cache: 12 MB I+D on chip per chip, 6 MB shared / 2 cores
Tertiary Cache: None
Other Cache: None
Memory Amount (GB): 8
# and size of DIMM: 4x2048MB
Memory Details: PC2-6400E-555 2Rx4
Power Supply Quantity and Rating (W): 1 x 350
Power Supply Details: Fujitsu Siemens Computers S26113-E520-V70
Disk Drive: 1 x WD5000AAKS (3.5", SATA, 7.2krpm, 500GB)
Disk Controller: Integrated SATA controller
# and type of Network Interface Cards (NICs) Installed: 1 x Broadcom 5755 NetXtreme Gigabit Ethernet (onboard)
NICs Enabled in Firmware / OS / Connected: 1/1/1
Network Speed (Mbit): 1000
Keyboard: KVM
Mouse: KVM
Monitor: KVM
Optical Drives: Yes
Other Hardware: None
Software
Power Management: Enabled (Server Balanced Processor Power and Performance)
Operating System (OS): Microsoft Windows Server 2003 R2 Enterprise x64 Edition
OS Version: 5.2.3790 Service Pack 1 Build 3790
Filesystem: NTFS
JVM Vendor: Bea Systems, Inc
JVM Version: BEA JRockit(R) (build R27.5.0-110-94909-1.6.0_03-20080204-1558-windows-x86_64, compiled mode)
JVM Command-line Options: -Xms3450m -Xmx3450m -Xns2900m -XXaggressive -Xlargepages -Xgc:genpar -XXcallprofiling -XXgcthreads=2 -XXtlasize:min=4k,preferred=512k -XXthroughputcompaction
JVM Affinity: start /affinity [03,0c]
JVM Instances: 4
JVM Initial Heap (MB): 3450
JVM Maximum Heap (MB): 3450
JVM Address Bits: 64
Boot Firmware Version: --
Management Firmware Version: --
Workload Version: SSJ 1.1
Director Location: Controller
Other Software: None
Boot Firmware Settings
--
Management Firmware Settings
--
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Fujitsu Siemens Computers
Model: PRIMERGY RX100 S3
CPU Description: Pentium D 925
Memory amount (GB): 2
Software
Operating System (OS): Windows Server 2003 Enterprise Edition SP1
JVM Vendor: BEA Systems, Inc.
JVM Version: BEA JRockit(R) (build R27.3.1-1-85830-1.6.0_01-20070716-1248-windows-ia32)
CCS Version: 1.1
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Infratek AG
Model: 107A-1/0.1
Serial Number: 08012092
Connectivity: RS-232
Input Connection: --
Calibration Institute: PTB (Physikalisch Technische Bundesanstalt)
Accredited by: CompuMess Elektronik GmbH
Calibration Label: 57653
Date of Calibration: 21-Jan-2008
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.2-13f4b0b4
Setup Description: --
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: Watchport Virtual Port 4.20.0.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: --
Notes
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 116 20.7
90% 113 20.6
80% 109 20.6
70% 105 20.6
60% 99.4 20.6
50% 93.0 20.6
40% 86.5 20.6
30% 79.0 20.6
20% 72.3 20.6
10% 66.0 20.6
Active Idle 59.3 20.6
Line Standard Minimum Temperature (°C) Elevation (m)
230V / 50 Hz / 1 phase / 2 wires 20.6 117
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     183,572
Calibration 2     185,257
Calibration 3     185,069
ssj_ops@calibrated=185,163
100% 99.5% 185,163 184,145
90% 90.1% 166,647 166,892
80% 79.7% 148,130 147,598
70% 70.5% 129,614 130,538
60% 59.7% 111,098 110,607
50% 49.4% 92,581 91,420
40% 40.6% 74,065 75,086
30% 30.1% 55,549 55,795
20% 20.0% 37,033 37,116
10% 10.0% 18,516 18,424
Active Idle   0 0
Graph of results