| Hewlett-Packard Company ProLiant DL580 G5 (Historical) | SPECpower_ssj2008 = 489 overall ssj_ops/watt | ||||
| Test Sponsor: | Intel Corp. | SPEC License #: | 3184 | Test Method: | Single Node |
| Tested By: | Principled Technologies, Inc. | Test Location: | Durham, NC, USA | Test Date: | Sep 2, 2010 |
| Hardware Availability: | Jan-2008 | Software Availability: | May-2009 | Publication: | Feb 23, 2011 |
| System Source: | Single Supplier | System Designation: | Server | Power Provisioning: | Line-powered |
| Target Load | Average Active Power (W) | Minimum Ambient Temperature (°C) |
|---|---|---|
| Calibration 1 | 627 | 20.9 |
| Calibration 2 | 627 | 21.0 |
| Calibration 3 | 628 | 21.0 |
| 100% | 627 | 21.1 |
| 90% | 611 | 21.0 |
| 80% | 591 | 21.0 |
| 70% | 566 | 20.9 |
| 60% | 538 | 21.0 |
| 50% | 511 | 21.1 |
| 40% | 490 | 21.1 |
| 30% | 472 | 21.1 |
| 20% | 455 | 21.0 |
| 10% | 438 | 21.0 |
| Active Idle | 418 | 21.0 |
| Power Analyzer pwr1 | |
|---|---|
| Hardware Vendor: | Yokogawa Electric International Pte. Ltd. |
| Model: | WT210 |
| Serial Number: | 91GB45373 |
| Connectivity: | RS-232 |
| Input Connection: | Default |
| Calibration Institute: | NIST |
| Accredited by: | Davis Calibration |
| Calibration Label: | 07-1673 |
| Date of Calibration: | 28-Jul-2010 |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| PTDaemon Version: | 1.4.0-7071d9e7 |
| Setup Description: | SUT Power Supply |
| Temperature Sensor temp1 | |
|---|---|
| Hardware Vendor: | Digi International Inc. |
| Model: | Watchport/H |
| Driver Version: | 5.10.26.0 |
| Connectivity: | USB |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| Setup Description: | 50 mm in front of SUT main air intake |
This benchmark result is intended to provide perspective on past power and/or performance using the historical hardware and/or software described on this result page.
The system as described on this result page was formerly generally available. At the time of this publication, it may not be shipping, and/or may not be supported, and/or may fail to meet other tests of General Availability described in the SPEC OSG Policy document, http://www.spec.org/osg/policy.html
This measured result may not be representative of the result that would be measured were this benchmark run with hardware and software available as of the publication date.
| Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
|---|---|---|---|---|---|---|---|
| Avg | Range | Avg | Range | ||||
| Calibration 1 | 207 | 300.0 | 3.18 | 5.0 | 0.952 | 627 | 0.4% |
| Calibration 2 | 211 | 300.0 | 3.13 | 5.0 | 0.948 | 627 | 0.4% |
| Calibration 3 | 211 | 300.0 | 3.13 | 5.0 | 0.948 | 628 | 0.4% |
| 100% | 211 | 300.0 | 3.13 | 5.0 | 0.948 | 627 | 0.4% |
| 90% | 211 | 300.0 | 3.06 | 5.0 | 0.947 | 611 | 0.4% |
| 80% | 211 | 300.0 | 2.96 | 5.0 | 0.945 | 591 | 0.4% |
| 70% | 211 | 300.0 | 2.84 | 5.0 | 0.943 | 566 | 0.4% |
| 60% | 211 | 300.0 | 2.71 | 5.0 | 0.941 | 538 | 0.5% |
| 50% | 211 | 300.0 | 2.58 | 5.0 | 0.938 | 511 | 0.5% |
| 40% | 212 | 300.0 | 2.48 | 5.0 | 0.936 | 490 | 0.5% |
| 30% | 211 | 300.0 | 2.39 | 5.0 | 0.934 | 472 | 0.5% |
| 20% | 211 | 300.0 | 2.31 | 5.0 | 0.932 | 455 | 0.5% |
| 10% | 211 | 300.0 | 2.23 | 5.0 | 0.931 | 438 | 0.5% |
| Active Idle | 211 | 300.0 | 2.13 | 5.0 | 0.931 | 418 | 0.5% |