Huawei Technologies Co., Ltd FusionServer RH2288 V3 | SPECpower_ssj2008 = NC overall ssj_ops/watt | ||||
Test Sponsor: | Huawei Technologies Co., Ltd | SPEC License #: | 3175 | Test Method: | Single Node |
Tested By: | Huawei Technologies Co., Ltd | Test Location: | Shenzhen, Guangdong, China | Test Date: | Oct 31, 2014 |
Hardware Availability: | Sep-2014 | Software Availability: | Sep-2012 | Publication: | Dec 1, 2014 |
System Source: | Single Supplier | System Designation: | Server | Power Provisioning: | Line-powered |
Set Identifier: | sut |
Set Description: | System Under Test |
# of Identical Nodes: | 1 |
Comment: | Single Node |
Hardware | |
---|---|
Hardware Vendor: | Huawei Technologies Co., Ltd |
Model: | FusionServer RH2288 V3 |
Form Factor: | 2U |
CPU Name: | Intel Xeon E5-2699V3 |
CPU Characteristics: | 18-Core, 2.3GHz, 45MB L3 Cache |
CPU Frequency (MHz): | 2300 |
CPU(s) Enabled: | 36 cores, 2 chips, 18 cores/chip |
Hardware Threads: | 72 (2 / core) |
CPU(s) Orderable: | 1,2 chips |
Primary Cache: | 32 KB I + 32 KB D on chip per core |
Secondary Cache: | 256 KB I+D on chip per core |
Tertiary Cache: | 45 MB I+D on chip per chip |
Other Cache: | None |
Memory Amount (GB): | 64 |
# and size of DIMM: | 8 x 8 GB |
Memory Details: | 8GB 2Rx8 PC4-2133P ECC RDIMM |
Power Supply Quantity and Rating (W): | 1 x 460 |
Power Supply Details: | Huawei P/N 02130957 |
Disk Drive: | 1 x 480GB SSD 2.5" SATA Huawei P/N 02310YDA with 1 x rear hard disk modules backplane |
Disk Controller: | Integrated SATA controller |
# and type of Network Interface Cards (NICs) Installed: | 1 x Qual-port BCM 5719 Gigabit Ethernet controller |
NICs Enabled in Firmware / OS / Connected: | 4/4/1 |
Network Speed (Mbit): | 1000 |
Keyboard: | None |
Mouse: | None |
Monitor: | None |
Optical Drives: | No |
Other Hardware: | None |
Software | |
---|---|
Power Management: | Power Saver Mode enabled in OS |
Operating System (OS): | Microsoft Windows Server 2012 Datacenter |
OS Version: | Version 6.2 (Build 9200) |
Filesystem: | NTFS |
JVM Vendor: | IBM Corporation |
JVM Version: | IBM J9 VM (build 2.6,JRE 1.7.0 Windows Server 2008 R2 amd64-64 20120322_106209 (JIT enabled, AOT enabled) |
JVM Command-line Options: | -Xaggressive -Xcompressedrefs -Xmn1706m -Xms2048m -Xmx2048m -XlockReservation -Xnoloa -XtlhPrefetch -Xlp -Xconcurrentlevel0 -Xthr:minimizeusercpu -Xgcthreads5 -Xgc:preferredHeapBase=0x80000000 |
JVM Affinity: | start /NODE [0,1,2,3] /AFFINITY [3F,FC0,3F000] |
JVM Instances: | 12 |
JVM Initial Heap (MB): | 2048 |
JVM Maximum Heap (MB): | 2048 |
JVM Address Bits: | 64 |
Boot Firmware Version: | V1.16 |
Management Firmware Version: | 5.29 |
Workload Version: | SSJ 1.2.10 |
Director Location: | Controller |
Other Software: | IBM WebSphere Application Server V8.5 for Windows on x86-64bit |
Hardware | |
---|---|
Hardware Vendor: | Huawei Technologies Co., Ltd |
Model: | Tecal RH1285 Rack Server |
CPU Description: | Intel Xeon 5606 |
Memory amount (GB): | 36 |
Software | |
---|---|
Operating System (OS): | Microsoft Windows Server 2003 SP2 |
JVM Vendor: | Oracle |
JVM Version: | Oracle Java HotSpot(TM) 64-Bit Server VM on Windows, version 1.6.0_29 |
CCS Version: | 1.2.6 |
Power Analyzer pwr1 | |
---|---|
Hardware Vendor: | Yokogawa Meters and Instruments Corporation |
Model: | WT210 |
Serial Number: | 91M412343 |
Connectivity: | RS-232 |
Input Connection: | Default |
Metrology Institute: | CNAS (China National Accreditation Service for Conformity Assessment) |
Accredited by: | Calibration and Testing Center of CEPREI |
Calibration Label: | B14006809-0032 |
Date of Calibration: | 05-Aug-2014 |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
PTDaemon Version: | 1.7.0-538b1562-20140802 |
Setup Description: | Connected to PSU 1 |
Temperature Sensor temp1 | |
---|---|
Hardware Vendor: | Digi |
Model: | Watchport/H |
Driver Version: | 5.70.105.0 |
Connectivity: | USB |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
Setup Description: | placed in front the main airflow inlet of the SUT less than 50mm. |