Sugon Sugon I620-G20 SPECpower_ssj2008 = 9,939 overall ssj_ops/watt
Test Sponsor: Sugon SPEC License #: 9046 Test Method: Single Node
Tested By: Sugon Test Location: Beijing, China Test Date: Jan 30, 2015
Hardware Availability: Jan-2015 Software Availability: Jun-2013 Publication: Mar 11, 2015
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.1% 3,161,325 264 11,964
90% 90.0% 2,870,546 240 11,976
80% 80.1% 2,552,481 217 11,745
70% 69.9% 2,229,034 196 11,383
60% 60.0% 1,913,249 175 10,908
50% 49.9% 1,590,719 156 10,186
40% 40.0% 1,274,762 139 9,166
30% 29.9% 954,090 122 7,806
20% 19.9% 634,351 107 5,933
10% 10.0% 318,891 91.3 3,491
Active Idle 0 52.5 0
∑ssj_ops / ∑power = 9,939
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: I620-G20.
Hardware
Hardware Vendor: Sugon
Model: Sugon I620-G20
Form Factor: 2U
CPU Name: Intel Xeon E5-2699 v3 2.30 GHz
CPU Characteristics: 18 Cores, 2.3GHz, 45MB L3 Cache
CPU Frequency (MHz): 2300
CPU(s) Enabled: 36 cores, 2 chips, 18 cores/chip
Hardware Threads: 72 (2 / core)
CPU(s) Orderable: 1,2 chips
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 256 KB I+D on chip per core
Tertiary Cache: 45 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 128
# and size of DIMM: 8 x 16 GB
Memory Details: 16GB 2Rx4 PC4-2133P ECC RDIMM; slots A0, B0, C0, D0, E0, F0, G0, H0 populated
Power Supply Quantity and Rating (W): 1 x 550
Power Supply Details: GW-CRPS550 PN:1197317
Disk Drive: Intel 530 series M.2 2242 type 120G SSD * 1 PN:SSDSCIHW120A4
Disk Controller: Onboard SATA controller
# and type of Network Interface Cards (NICs) Installed: 1 x Dual port Intel I210 Gigabit Ethernet Controller
NICs Enabled in Firmware / OS / Connected: 2/1/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Power Saver Mode enabled ( details see SUT Notes)
Operating System (OS): Microsoft Windows Server 2008 R2 SP1 DC
OS Version: Version 6.1.7601 Service Pack 1 Build 7601
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM (build 2.6,JRE 1.7.0 Windows Server 2008 R2 amd64-64 20120322_106209 (JIT enabled,AOT enabled)
JVM Command-line Options: -Xmn1400m -Xms1875m -Xmx1875m -Xaggressive -Xcompressedrefs -Xgcpolicy:gencon -XlockReservation -Xnoloa -XtlhPrefetch -Xlp -Xconcurrentlevel0 -Xthr:minimizeusercpu -Xgcthreads6 -Xgc:preferredHeapBase=0x80000000
JVM Affinity: start /NODE [0, 1, 2, 3]/affinity [3F,FC0,3F000]
JVM Instances: 12
JVM Initial Heap (MB): 1875
JVM Maximum Heap (MB): 1875
JVM Address Bits: 64
Boot Firmware Version: 083
Management Firmware Version: 085
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: IBM WebSphere Application Server V8.5.0.0, Microsoft Hotfix for Windows (KB2510206)
Boot Firmware Settings
Management Firmware Settings
none
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Sugon
Model: I620-G15
CPU Description: E5-2660 v2
Memory amount (GB): 24
Software
Operating System (OS): Microsoft Windows Server 2008 R2 Enterprise Edition SP 1
JVM Vendor: Oracle Corporation
JVM Version: Java HotSpot(TM) 64-Bit Server VM, version 1.7.0_25
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: YOKOGAWA Meters and Instruments Corporation
Model: WT310
Serial Number: C2PB07002V
Connectivity: USB2
Input Connection: Default
Metrology Institute: CNAS
Accredited by: CTI (Centre Testing International Corporation)
Calibration Label: QEB14002935-07
Date of Calibration: 30-Jan-2015
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.7.0-538b1562-20140802
Setup Description: Connect to PSU1
Temperature Sensor temp1
Hardware Vendor: iButtonLink
Model: Tsense
Driver Version: 2.8.30.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: less than 50mm in front of SUT main air intake
Notes
SPECpower_ssj.props input.load_level.number_warehouses set to 72 for a known issue with this java version.
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 264 24.8
90% 240 25.1
80% 217 25.1
70% 196 25.0
60% 175 24.9
50% 156 24.8
40% 139 24.9
30% 122 24.8
20% 107 24.8
10% 91.3 24.9
Active Idle 52.5 24.9
Line Standard Minimum Temperature (°C) Elevation (m)
220V / 50 Hz / 1 phase / 2 wires 24.8 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     3,276,905
Calibration 2     3,192,469
Calibration 3     3,184,466
ssj_ops@calibrated=3,188,468
100% 99.1% 3,188,468 3,161,325
90% 90.0% 2,869,621 2,870,546
80% 80.1% 2,550,774 2,552,481
70% 69.9% 2,231,927 2,229,034
60% 60.0% 1,913,081 1,913,249
50% 49.9% 1,594,234 1,590,719
40% 40.0% 1,275,387 1,274,762
30% 29.9% 956,540 954,090
20% 19.9% 637,694 634,351
10% 10.0% 318,847 318,891
Active Idle   0 0
Graph of results