Hewlett Packard Enterprise Synergy 480 Gen10 Compute Module | SPECpower_ssj2008 = 10,825 overall ssj_ops/watt | ||||
Test Sponsor: | Hewlett Packard Enterprise | SPEC License #: | 3 | Test Method: | Multi Node |
Tested By: | Hewlett Packard Enterprise | Test Location: | Houston, TX, USA | Test Date: | Mar 12, 2019 |
Hardware Availability: | Apr-2019 | Software Availability: | Mar-2019 | Publication: | Apr 2, 2019 |
System Source: | Single Supplier | System Designation: | Server | Power Provisioning: | Line-powered |
Target Load | Average Active Power (W) | Minimum Ambient Temperature (°C) |
---|---|---|
Calibration 1 | 3,950 | 23.4 |
Calibration 2 | 3,959 | 23.5 |
Calibration 3 | 3,969 | 23.6 |
100% | 3,958 | 23.7 |
90% | 3,588 | 23.8 |
80% | 3,130 | 23.8 |
70% | 2,664 | 23.8 |
60% | 2,339 | 23.7 |
50% | 2,053 | 23.7 |
40% | 1,789 | 23.7 |
30% | 1,541 | 23.7 |
20% | 1,314 | 23.5 |
10% | 1,110 | 23.6 |
Active Idle | 598 | 23.5 |
Power Analyzer pwr1 | |
---|---|
Hardware Vendor: | Yokogawa |
Model: | WT210 |
Serial Number: | 91GB53024 |
Connectivity: | GPIB vi NI GPIB-USB-HS |
Input Connection: | Default |
Metrology Institute: | NIST |
Accredited by: | TRANSCAT |
Calibration Label: | 5-EM5Y4-80-1 |
Date of Calibration: | 21-Jun-2018 |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
PTDaemon Version: | 1.8.1-260d064e-20161220 |
Setup Description: | SUT Power Supply 5 |
Power Analyzer pwr2 | |
---|---|
Hardware Vendor: | Yokogawa |
Model: | WT210 |
Serial Number: | 91GB47168 |
Connectivity: | GPIB vi NI GPIB-USB-HS |
Input Connection: | Default |
Metrology Institute: | NIST |
Accredited by: | TRANSCAT |
Calibration Label: | 5-EM5Y4-60-1 |
Date of Calibration: | 21-Jun-2018 |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
PTDaemon Version: | 1.8.1-260d064e-20161220 |
Setup Description: | SUT Power Supply 3 |
Power Analyzer pwr3 | |
---|---|
Hardware Vendor: | Yokogawa |
Model: | WT210 |
Serial Number: | 91GC21887 |
Connectivity: | GPIB vi NI GPIB-USB-HS |
Input Connection: | Default |
Metrology Institute: | NIST |
Accredited by: | TRANSCAT |
Calibration Label: | 5-EM5Y4-20-1 |
Date of Calibration: | 21-Jun-2018 |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
PTDaemon Version: | 1.8.1-260d064e-20161220 |
Setup Description: | SUT Power Supplies 1 and 2 |
Temperature Sensor temp1 | |
---|---|
Hardware Vendor: | Digi International Inc. |
Model: | Watchport/H |
Driver Version: | 5.70.105.0 |
Connectivity: | USB |
PTDaemon Host System: | same as CCS |
PTDaemon Host OS: | same as CCS |
Setup Description: | 5 mm in front of SUT main intake |
Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
---|---|---|---|---|---|---|---|
Avg | Range | Avg | Range | ||||
Calibration 1 | 214 | 300.0 | 4.36 | 20.0 | 0.993 | 925 | 0.8% |
Calibration 2 | 214 | 300.0 | 4.37 | 20.0 | 0.993 | 929 | 0.8% |
Calibration 3 | 214 | 300.0 | 4.39 | 20.0 | 0.993 | 932 | 0.8% |
100% | 214 | 300.0 | 4.38 | 20.0 | 0.993 | 929 | 0.8% |
90% | 214 | 300.0 | 3.99 | 20.0 | 0.993 | 846 | 0.9% |
80% | 214 | 300.0 | 3.51 | 10.0 | 0.990 | 743 | 0.6% |
70% | 214 | 300.0 | 3.08 | 10.0 | 0.988 | 650 | 0.6% |
60% | 214 | 300.0 | 2.74 | 10.0 | 0.985 | 577 | 0.7% |
50% | 214 | 300.0 | 2.41 | 10.0 | 0.980 | 506 | 0.8% |
40% | 214 | 300.0 | 2.08 | 10.0 | 0.973 | 434 | 0.9% |
30% | 214 | 300.0 | 1.75 | 5.0 | 0.961 | 359 | 0.6% |
20% | 214 | 300.0 | 1.45 | 5.0 | 0.945 | 293 | 0.7% |
10% | 215 | 300.0 | 1.17 | 2.0 | 0.910 | 229 | 0.5% |
Active Idle | 215 | 300.0 | 0.774 | 1.0 | 0.778 | 129 | 0.5% |
Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
---|---|---|---|---|---|---|---|
Avg | Range | Avg | Range | ||||
Calibration 1 | 213 | 300.0 | 9.70 | 20.0 | 0.996 | 2,056 | 0.5% |
Calibration 2 | 213 | 300.0 | 9.72 | 20.0 | 0.996 | 2,060 | 0.5% |
Calibration 3 | 213 | 300.0 | 9.74 | 20.0 | 0.996 | 2,065 | 0.5% |
100% | 213 | 300.0 | 9.74 | 20.0 | 0.996 | 2,062 | 0.5% |
90% | 213 | 300.0 | 8.82 | 20.0 | 0.995 | 1,867 | 0.5% |
80% | 213 | 300.0 | 7.60 | 10.0 | 0.993 | 1,607 | 0.4% |
70% | 213 | 300.0 | 6.44 | 10.0 | 0.991 | 1,361 | 0.4% |
60% | 213 | 300.0 | 5.67 | 10.0 | 0.989 | 1,196 | 0.4% |
50% | 214 | 300.0 | 5.00 | 10.0 | 0.985 | 1,051 | 0.5% |
40% | 214 | 300.0 | 4.40 | 10.0 | 0.980 | 922 | 0.5% |
30% | 214 | 300.0 | 3.86 | 5.0 | 0.974 | 803 | 0.4% |
20% | 214 | 300.0 | 3.35 | 5.0 | 0.966 | 692 | 0.4% |
10% | 214 | 300.0 | 2.97 | 5.0 | 0.957 | 608 | 0.5% |
Active Idle | 214 | 300.0 | 1.77 | 5.0 | 0.860 | 326 | 0.7% |
Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
---|---|---|---|---|---|---|---|
Avg | Range | Avg | Range | ||||
Calibration 1 | 211 | 300.0 | 4.62 | 10.0 | 0.993 | 969 | 0.5% |
Calibration 2 | 211 | 300.0 | 4.63 | 10.0 | 0.993 | 971 | 0.5% |
Calibration 3 | 211 | 300.0 | 4.63 | 10.0 | 0.993 | 972 | 0.5% |
100% | 211 | 300.0 | 4.61 | 10.0 | 0.993 | 967 | 0.5% |
90% | 211 | 300.0 | 4.18 | 10.0 | 0.992 | 875 | 0.5% |
80% | 211 | 300.0 | 3.73 | 10.0 | 0.990 | 780 | 0.6% |
70% | 211 | 300.0 | 3.14 | 10.0 | 0.986 | 654 | 0.6% |
60% | 211 | 300.0 | 2.73 | 5.0 | 0.982 | 566 | 0.5% |
50% | 212 | 300.0 | 2.40 | 5.0 | 0.977 | 495 | 0.5% |
40% | 212 | 300.0 | 2.11 | 5.0 | 0.969 | 433 | 0.5% |
30% | 211 | 300.0 | 1.86 | 5.0 | 0.961 | 379 | 0.6% |
20% | 211 | 300.0 | 1.64 | 5.0 | 0.951 | 330 | 0.7% |
10% | 212 | 300.0 | 1.38 | 5.0 | 0.931 | 273 | 0.8% |
Active Idle | 212 | 300.0 | 0.842 | 2.0 | 0.795 | 142 | 0.7% |