
naa.600c0ff000db1eb09e3a7a4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000db1eb09e3a7a4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T0:L2
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T0:L2

naa.600c0ff0001193a1d8fb5b4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff0001193a1d8fb5b4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}{TPG_id=1,TPG_state=ANO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T1:L2
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T1:L2

naa.600c0ff000113a7f6864344e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113a7f6864344e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T5:L2
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T5:L2

naa.600c0ff00010f63a5864344e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff00010f63a5864344e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T5:L1
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T5:L1

naa.600c0ff000db1ed60000000000000000:
   Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff000db1ed60000000000000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T0:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T0:L0

naa.600c0ff000113a7f4864344e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113a7f4864344e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T5:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T5:L0

naa.600c0ff00010f63a0000000000000000:
   Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff00010f63a0000000000000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T5:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T5:L0

naa.600c0ff000db1f3a7c647a4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000db1f3a7c647a4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T3:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T3:L0

naa.600c0ff0001193a1b0fb5b4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff0001193a1b0fb5b4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T1:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T1:L0

naa.600c0ff00011926a0000000000000000:
   Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff00011926a0000000000000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T4:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T4:L0

naa.600c0ff000113a4661fd5f4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113a4661fd5f4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T2:L2
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T2:L2

naa.600c0ff000db3da50000000000000000:
   Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff000db3da50000000000000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T3:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T3:L0

naa.600c0ff0001193c60000000000000000:
   Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff0001193c60000000000000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T1:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T1:L0

naa.600c0ff000113a4631fd5f4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000113a4631fd5f4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T2:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T2:L0

naa.600c0ff0001194034cfd5f4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff0001194034cfd5f4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T2:L1
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T2:L1

naa.600c0ff000db1ed6883a7a4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000db1ed6883a7a4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T0:L1
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T0:L1

naa.600c0ff00011926ace035c4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff00011926ace035c4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T4:L1
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T4:L1

naa.600c0ff0001130ee0000000000000000:
   Device Display Name: HP Fibre Channel Enclosure Svc Dev (naa.600c0ff0001130ee0000000000000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T2:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T2:L0

naa.600c0ff0001193c6c0fb5b4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff0001193c6c0fb5b4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T1:L1
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T1:L1

naa.600508b1001cac934c05db8e0178fc10:
   Device Display Name: HP Serial Attached SCSI Disk (naa.600508b1001cac934c05db8e0178fc10)
   Storage Array Type: VMW_SATP_LOCAL
   Storage Array Type Device Config: SATP VMW_SATP_LOCAL does not support device configuration.
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba2:C0:T0:L1
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba2:C0:T0:L1

naa.600c0ff000db1f3aa1647a4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000db1f3aa1647a4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T3:L2
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T3:L2

naa.600c0ff000119331b4035c4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000119331b4035c4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T4:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T4:L0

naa.600c0ff000db1eb0753a7a4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000db1eb0753a7a4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T0:L0
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T0:L0

naa.600c0ff000119331e1035c4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000119331e1035c4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=ANO}{TPG_id=0,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba4:C0:T4:L2
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba4:C0:T4:L2

naa.600c0ff000db3da58d647a4e01000000:
   Device Display Name: HP Fibre Channel Disk (naa.600c0ff000db3da58d647a4e01000000)
   Storage Array Type: VMW_SATP_ALUA
   Storage Array Type Device Config: {implicit_support=on;explicit_support=off; explicit_allow=on;alua_followover=on;{TPG_id=1,TPG_state=AO}}
   Path Selection Policy: VMW_PSP_MRU
   Path Selection Policy Device Config: Current Path=vmhba3:C0:T3:L1
   Path Selection Policy Device Custom Config: 
   Working Paths: vmhba3:C0:T3:L1

